Multi-level PIR signal processing
Advanced 90° photoelectric detection pattern
and patented smoke chamber for superior
detection and dust resistance
Unique high signal-to-noise ratio and superior
RFI immunity to prevent false alarms
Excellent smoke access provides reliable detection
for all smoke flow directions and velocities
User verification of sensitivity
Solid-state LED indicator light
Locking/non-locking
mounting plate
Attractive styling for any decor
UL and ULC listed
Photoelectric
Smoke Detectors
& Alarms
Advanced 90° Detection Pattern
With its advanced 90° photoelectric detection pattern, Meridian offers
superior detection of smoldering or rapid growth fires under a broad
range of applications and changing environmental conditions.
Patented Smoke Chamber Design
Detects Smoke – Not Dust
Meridian’s exclusive detection pattern smoke chamber design cannot
be found in just any ordinary smoke detector. Meridian’s design offers
greater sensitivity to smoke while at the same time better immunity to
dust, insects and other environmental factors - conditions that may
leave a lesser quality smoke detector impaired and unable to
alert you to danger.
Heat Detector Option
In addition to its superior ability to detect smoke, Meridian offers you
yet another critical safeguard - it is available with a built-in sensor
designed to detect the presence of heat caused by a fire that starts
and develops very rapidly.
Status Indicator
With a quick glance at the LED indicator located at the top of your
Meridian unit, you can see in an instant if the smoke detector is ‘on’
or its alarm/trouble/normal status.
Meridian is setting a new standard for
reliability and performance with a photoelectric
design so revolutionary it’s covered by two
patents. With 2-wire, 4-wire and wireless
versions, and all the options for relay type,
local sounder and fixed temperature sensor,
Meridian is ready for your next security or
fire alarm installation.
• 20 • • 21 •
V+
V–
12 to 24 VDC
+ I
NO
+
I
NO
+ I
COM
NC
NO
To
Interconnected
Units
I/O
COM
COM
COM
NC
NO
I/O
NU
I/O
To
Interconnected
Units
WIRING
DIAGRAM
V+
V
12 to 24 VDC
End of Line
Device
AUX RelayAUX Relay
+ + I + + I + + I
NC
NO
C
NC
NO
C
WIRING DIAGRAM
RED solid state LED indicator light
Optional Form 'C' auxiliary relay
57°C (135°F) fixed temperature heat sensor option
Magnet-activated sensitivity test switch
ULC listed S529/UL listed UL268
Nominal operating voltage ................................12 - 24VDC or Vfwr
Maximum operating volt. range ........................10 - 30VDC or 10 - 26.4Vfwr
MODELS
MN220
2-wire detector
MN220T
2-wire detector, fixed temp 135°F (57°C) sensor
MN220R
2-wire detector, Form 'C' auxiliary relay
MN220RT
2-wire detector, Form 'C' auxiliary relay,
fixed temp 135°F (57°C) sensor
MN-220 SERIES - 2-WIRE SMOKE DETECTORS
MN-140 SERIES - DC POWERED SMOKE ALARM
GREEN solid-state LED indicator light
Loud 85dB piezoelectric alarm sounder
Interconnect up to 20 detectors
Removable terminals for easier wiring
Optional Form ‘A’ (normally open, alarm closed) and/or Form ‘C’ (normally
open/normally closed) alarm relays
57
o
C (135
o
F) fixed temperature heat sensor option
Test Button for user to perform sensitivity test
Automatic self-test every 40 seconds with audible trouble indication if the
detector has insufficient smokesensitivity
ULC listed S531
MODELS
MN-140
Form 'A' alarm relay, sounder, interconnect
MN-140T
As MN-140 plus 57
o
C (135
o
F) sensor
MN-140R
As MN-140 plus Form ‘C’ auxiliary relay
MN-140RT
As MN-140 with Form ‘C’ auxiliary relay, 57
o
C (135
o
F) sensor
MN-140C
Form ‘C’ alarm relay, sounder, interconnect
MN-140CT
As MN-140C plus 57
o
C (135
o
F) sensor
MN-140CH
As MN-140C plus isolated 57
o
C (135
o
F) sensor as
heat detector with Form ‘A’ relay
MODELS
MN240
Form 'A' alarm relay
MN240T
Form 'A' alarm relay, fixed temp 57°C (135°F) sensor
MN240R
Form 'A' alarm relay, Form 'C' auxiliary relay
MN240RT
Form 'A' alarm relay, Form 'C' auxiliary relay,
fixed temp 57°C (135°F) sensor
MN240S
Form 'A' alarm relay, 85dB sounder
MN240ST
Form 'A' alarm relay, 85dB sounder,
fixed temp 57°C (135°F) sensor
MN240SR
Form 'A' alarm relay, 85dB sounder, Form 'C' auxiliary relay
MN240SRT
Form 'A' alarm relay, 85dB sounder, Form 'C'
auxiliary relay, fixed temp 57°C (135°F) sensor
RED solid state LED indicator light
Audible trouble indication (in sounder-equipped units)
if the unit has insufficient smoke sensitivity
ULC listed S529/UL listed UL 268
Nominal operating voltage ................................12 - 24VDC or Vfwr
Maximum operating volt. range ........................10 - 30VDC or 10 - 26.4Vfwr
Alarm
Initiating
Circuit
V+
V–
12 to 24 VDC
EOL
Resistor
End of Line
Device
AUX RelayAUX Relay
+
+
I
NO
C
+
+
I
NO
C
+
+
I
NO
C
C
NC
NO
C
NC
NO
WIRING DIAGRAM